A: We are factory. A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity. A: Yes, we could offer the sample for free charge but do not pay the cost of freight. A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shippment. A: We are factory. A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity. A: Yes, we could offer the sample for free charge but do not pay the cost of freight. A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shippment. SEM wheel loader 50F, 650 Air Conditioner, Lonking 855 air conditioner, Liugong loader ZL50CN, 855N, 856 air conditioner, SDLG wheel loader 956L 952H 953 air conditioner, XCMG wheel loader air conditioner LW500KL ZL50GN, Komatsu WA380, WA380-3, WA380-5, WA430-5 air conditioner Air Conditioner Air Conditioner,Air Conditioner Of Sdlg Loader,Air Conditioner Of Xcmg Loader,Warm Machine Of Xgma Loader Shandong Tianfu International Trade Co.,Ltd. , https://www.tfloaderparts.com
Pump
>> Pump Body: cast iron & support under special anti-rust treatment
>>Â Impeller: stainless steel impeller, brass impeller, ppo impeller
>>Â Mechnical Seal: carbon / ceramic / Stainless Steel
Motor
>> Bulit-in thermal protector for single phase motor
>> Motor with copper winding
>>Â Motor Housing: Steel-plate, Aluminum alloy
>> C&U bearing
>>Â AISI 304 shaft or 45#Â carbon steel
Working Range
>> Liquid: clean liquids without suspended solids, non-aggressive
>> Liquid temperature: -10ºC and +100ºC
>> Ambient temperature up to +40ºC
>> Max. working pressure 10 bar
>> Continous service S1
>> Insulation: B
>> Protection: IP44
Advantages
>> Electronic pressure switch controlled by PC clip to avoid take off pressure switch frequently.
>> Every 72h it will start for 10s in order to avoid pump locked if long time no using pump.
>> Water protection system to avoid the pump in the anhydrous state for a long time.Â
>> Delay 3s start to avoid spark-over socket, protect the personal safety.
>>Â The flow priority system, electric pump use acme, turely achieve the full pressure.Â
Application
                                                                    Â
Model
HP
W
Current (A)
Capacitor (uf)
H.Max (M)
Q.Max (L/min)
Pipe Size
Pressure Set (bar)
Tank (L)
GDHm-125A
0.15
125
1.5
8
30
32
1"X1"
1.5
2
GDHm-250A
0.35
250
3.5
10
32
35
1"X1"
1.8
2
GDHm-370A
0.5
370
4.5
10
36
36
1"X1"
2.2
2
GDHm-550A
0.75
550
2.9
15
45
55
1"X1"
2.6
2
GDHm-750A
1
750
3.5
20
55
58
1"X1"
2.8
2
GDHm-1100A
1.5
1100
4.5
25
62
66
1"X1"
3.2
2
GDHm Automatic Self-priming Pump   Â
    Â
ItemÂ
Description
ItemÂ
Description
ItemÂ
Description
ItemÂ
Description
11
Press Sensor
21
Bearing
31
Screw
41
O-ring
12
Screw
22
Shaft Key
32
Cable Plug
42
Pressure Tank
13
Inlet Rubber
23
Rator
33
Cable Net
43
Pressure Sensor
14
Stainless steel Inlet
24
Bearing
34
Screw
44
Cover
15
O-ring
25
Stator
35
PC Clip
45
Plastic Base
16
Screw
26
Motor HouseÂ
36
Volatede Regulator
46
Screw
17
O-ring
27
Terminal Box
37
O-ring
Â
Â
18
Screw
28
Screw
38
Fan
Â
Â
19
Front Plate
29
Capacitor
39
Screw
Â
Â
20
Screw
30
Terminal Box
40
Fan Cover
Â
Â
Production Work-flow Chart of Pump
Â
                           About Us
                                 Â
FAQQ: Are you trading company or manufacturer ?
Q: How long is your delivery time?
Q: Do you provide samples ? is it free or extra ?
Q: What is your terms of payment ?
Pump
>> Pump Body: cast iron & support under special anti-rust treatment
>>Â Impeller: stainless steel impeller, brass impeller, ppo impeller
>>Â Mechnical Seal: carbon / ceramic / Stainless Steel
Motor
>> Bulit-in thermal protector for single phase motor
>> Motor with copper winding
>>Â Motor Housing: Steel-plate, Aluminum alloy
>> C&U bearing
>>Â AISI 304 shaft or 45#Â carbon steel
Working Range
>> Liquid: clean liquids without suspended solids, non-aggressive
>> Liquid temperature: -10ºC and +100ºC
>> Ambient temperature up to +40ºC
>> Max. working pressure 10 bar
>> Continous service S1
>> Insulation: B
>> Protection: IP44
Advantages
>> Electronic pressure switch controlled by PC clip to avoid take off pressure switch frequently.
>> Every 72h it will start for 10s in order to avoid pump locked if long time no using pump.
>> Water protection system to avoid the pump in the anhydrous state for a long time.Â
>> Delay 3s start to avoid spark-over socket, protect the personal safety.
>>Â The flow priority system, electric pump use acme, turely achieve the full pressure.Â
Application
                                                                    Â
Model
HP
W
Current (A)
Capacitor (uf)
H.Max (M)
Q.Max (L/min)
Pipe Size
Pressure Set (bar)
Tank (L)
GDHm-125A
0.15
125
1.5
8
30
32
1"X1"
1.5
2
GDHm-250A
0.35
250
3.5
10
32
35
1"X1"
1.8
2
GDHm-370A
0.5
370
4.5
10
36
36
1"X1"
2.2
2
GDHm-550A
0.75
550
2.9
15
45
55
1"X1"
2.6
2
GDHm-750A
1
750
3.5
20
55
58
1"X1"
2.8
2
GDHm-1100A
1.5
1100
4.5
25
62
66
1"X1"
3.2
2
GDHm Automatic Self-priming Pump   Â
    Â
ItemÂ
Description
ItemÂ
Description
ItemÂ
Description
ItemÂ
Description
11
Press Sensor
21
Bearing
31
Screw
41
O-ring
12
Screw
22
Shaft Key
32
Cable Plug
42
Pressure Tank
13
Inlet Rubber
23
Rator
33
Cable Net
43
Pressure Sensor
14
Stainless steel Inlet
24
Bearing
34
Screw
44
Cover
15
O-ring
25
Stator
35
PC Clip
45
Plastic Base
16
Screw
26
Motor HouseÂ
36
Volatede Regulator
46
Screw
17
O-ring
27
Terminal Box
37
O-ring
Â
Â
18
Screw
28
Screw
38
Fan
Â
Â
19
Front Plate
29
Capacitor
39
Screw
Â
Â
20
Screw
30
Terminal Box
40
Fan Cover
Â
Â
Production Work-flow Chart of Pump
Â
                           About Us
                                 Â
FAQQ: Are you trading company or manufacturer ?
Q: How long is your delivery time?
Q: Do you provide samples ? is it free or extra ?
Q: What is your terms of payment ?
The scorching summer is here. I think all of you are taking measures to reduce the sun and heat. Today I summarized the basic knowledge and installation skills of the loader air conditioning system to share with the majority of loader drivers and friends, so that you can enjoy this summer To a cool driving environment.
1. The composition of the loader air conditioning system
The air conditioning systems used on loaders all use a method called evaporative compression refrigeration system. This system consists of a compressor, condenser, liquid storage and drying bottle, expansion valve and evaporator. These components are connected by aluminum pipes or hoses, and the refrigerant is placed in this sealed piping system (refrigeration cycle).
Second, the principle of air conditioning refrigeration cycle
The air-conditioning compressor is driven to rotate by the engine. The high-temperature and high-pressure refrigerant vapor discharged from the compressor enters the condenser through the high-pressure hose. Because the temperature of the high-temperature and high-pressure refrigerant vapor is higher than the temperature of the air outside the car, the condenser fan is used to make the condenser The heat of the refrigerant vapor is taken away by the air outside the vehicle, condensing the high temperature and high pressure refrigerant vapor into a higher temperature and high pressure liquid, which flows into the drying bottle through the high pressure hose, and flows through the expansion valve after being dried and filtered.
Under the throttling action of the expansion valve, the refrigerant becomes a low-temperature, low-pressure liquid and enters the air-conditioning evaporator. It vaporizes at a constant pressure and absorbs the heat of the air outside the evaporator tube, so that the air flowing through the evaporator is circulated in the Cabin. The lowered temperature becomes cold air, which is sent into the cabin by a blower to lower the air temperature in the cabin. The vaporized refrigerant vapor is sucked and compressed by the compressor, and then becomes high-temperature, high-pressure refrigerant gas, which is pressed into the condenser through a high-pressure hose, completing a refrigeration cycle of the air conditioning system.
Three, operation panel instructions
The control panel on the outer cover is as shown in the figure. The functions of these switches and indicators are:
1. Refrigeration switch: used to control the work of the air-conditioning compressor.
2. Air volume switch; used to control the speed of the evaporator fan in order to select the appropriate air volume.
3. Indicator light: red light on means that the blower is running and the system is working; green light on means that the compressor is started and the refrigeration system is working.
Adjusting the angle of the air outlet can change the angle and direction of the cold air blowing; adjusting the air volume switch can obtain three levels of air volume: high, medium and low.
Fourth, the installation skills of the main components
The installation of the main components is a crucial part of the air conditioning system debugging. The quality of the main components of the air conditioner is completed by the supplier and the OEM. The main components of the air conditioner can only be regarded as semi-finished products from the supplier to the OEM. They must The system can be connected through the OEM to form a complete body. Therefore, the quality of the installation of air conditioners in the production line of the main engine factory directly affects the quality of the air conditioning system.
Unscrew the dust cap when the compressor pipe heads are connected. Do not place the pipe heads below the level to prevent lubricant leakage. When connecting the belt with the driving pulley, check the belt tension straightness, and the allowable error is between 0~1.5 mm. The method of checking the belt tension is as follows: use the middle finger to forcefully press down on the center belt point of the two wheels, the elastic pressure range is between 4~7mm.
During the transportation process of the condenser assembly, be careful to handle it gently, and do not damage the collecting pipe and rectangular pipe to prevent refrigerant leakage. When installing, pay attention to the big pipe head facing up and the small pipe head down. Unscrew the dust cap when the pipe heads are connected. When the pipe head is locked, use two wrenches to tighten it in opposite directions, because the condenser is Aluminum, so pay attention to force to prevent the lock from breaking. Avoid high-temperature areas and sharp-angle areas when wiring lines to prevent burns or wear.
The liquid storage drying bottle should be opened after the preparations are completed to prevent the inhalation of moisture in the air. There is a glass sight glass on the head of the liquid storage drying bottle. Be careful not to scratch it to prevent refrigerant leakage. Pay special attention to the butt joint of the tube head. The direction of the arrow on the end marked with "â†" on the liquid storage drying bottle must be connected to the evaporator.
During the transportation process of the evaporator assembly, be careful to handle with care and do not damage the pipeline to prevent refrigerant leakage. Unscrew the dust cap when the pipe heads are connected. When the pipe head is locked, use two wrenches to tighten it in opposite directions, so that the expansion valve cannot be loosened.
5
The hot summer has come, and the main components of the air-conditioning system have become the main loss materials in the season. A loader without an air-conditioning system cannot be regarded as a complete machine. Drivers and friends will inevitably have to drive the loader in an environment without cooling. All kinds of discomfort, which easily increase the operational risk. To understand the basic knowledge of the loader air conditioning system, master the installation skills of the main components, to ensure that the loader air conditioning system can be stably refrigerated, and to create a cool and comfortable driving environment, which is very important to our loader drivers
Model NO.: GDHm-125A, 250A, 370A, 550A, 750A, 1100A
Power: Electric
Start Up: Electric Pump
Type: Blade Pump
Application: Clarified Water Pump
Industry: Clean Water Pump
Media: Clean Water
Performance: Automatic Pump
Theory: Vortex Pump
Motor Shaft: 45#/304# Stainliss Steel
Impeller: Brass/Stainless Steel/PPO
Brand: OEM
Motor Sheet: Cold Silicon Rolling Sheet
Mechanical Seal: NBR/Ceramic/Carbon
Insulation: B/F
Protection: IP44
Rator: Silicon Steel Sheet Cold Rolling
Stator: Silicon Steel Sheet Cold Rolling
Trademark: GORDON
Transport Package: Foam+Carton+Pallet
Specification: Jet Pump
Origin: Fu′an China
HS Code: 8413709990
Model NO.: GDHm-125A, 250A, 370A, 550A, 750A, 1100A
Power: Electric
Start Up: Electric Pump
Type: Blade Pump
Application: Clarified Water Pump
Industry: Clean Water Pump
Media: Clean Water
Performance: Automatic Pump
Theory: Vortex Pump
Motor Shaft: 45#/304# Stainliss Steel
Impeller: Brass/Stainless Steel/PPO
Brand: OEM
Motor Sheet: Cold Silicon Rolling Sheet
Mechanical Seal: NBR/Ceramic/Carbon
Insulation: B/F
Protection: IP44
Rator: Silicon Steel Sheet Cold Rolling
Stator: Silicon Steel Sheet Cold Rolling
Trademark: GORDON
Transport Package: Foam+Carton+Pallet
Specification: Jet Pump
Origin: Fu′an China
HS Code: 8413709990
 Electric Copper Wire Self-priming Auto Water Pump with Pump Impeller
Technical Data
Â
Technical Data
Â