XI'AN TAIMA BIOLOGICAL ENGINEERING CO.LTD , https://www.taimabio.com
Installation, Use & Maintenance:
1. Before Installation, it's necessary to clean the valve and remove possible defects caused in the transportation process.
2.Check carefully whether marks and the nameplate on the valve meet operating requirements.
3. This valve can be insstalled on pipelines at any angle.
4. This valve shall be fully open or fully closed in running and not be used as a throttle valve, or else its sealing surfaces will be washed and get worn faster.
5. For Long term storage, it shall be stored in a dry and ventilated room whth periodic check to avoid rust.
6. Knocking shall be avoided in the transportation process.
Structural Features:
1. Use a Cylinder as the actuator to drive the gate directly to move up and down, with fast opening/closing.
2. The double gates adopt floating connection to produce reliable one-way seal under the medium pressure action. Also the floating connection can drive the gate to rotate up in opening/closing due to misaliginment of axial lines so that the friction grains between the valves' gate and seat are distributed evenly to produce no linear abrasion, thus improving its service life greatly.
3. Sealing surfaces of the valve's body and gate are lined with anti-wear ceramics, with excellent resistance to abrasion.
4. Being compact, it's easy for transportation, installation and maintenance.
Working Principle
When the cylinder drives the gate to move downwards through the valve's stem, sealing surfaces of the valve's gate and body will be engaged to cut off the channel, namely, closing; the other way around is opening.
Main Parts and Materials
Sr No.
Parts
Material
Sr No.
Parts
Material
1
Body
WCB
7
Middle Body
WCB
2
Disc
Ceramic
8
Packing
Flexible Graphite
3
Seat
Ceramic
9
Packing Gland
2Cr13
4
Stem
2Cr13
10
Bracket
Q235
5
Stud
35CrMoVA
11
Pneumatic Actuator
Aluminum Body
6
Nut
25
Â
Â
Â
Application Specification
1. Design and Manufacture: GB/T 12224
2. Face to Face Dimension: Manufacturer's Standard
3. Flange Dimension: JB/T 79.1, ANSI B16.5 Â DIN 2543, JIS B2020
4. Inspection and Test: GB/T 9092
5. Material Standard: GB/T 12229 for Carbon Steel, GB/T 12230 for Stainless Steel
Main External and connecting Dimensions
DN
PN
L
D
D1
C
H
n-d
Â
50
10
200
160
125
16
520
4-18
Â
65
220
180
145
18
595
4-18
Â
80
240
195
160
20
635
8-18
Â
100
280
215
180
20
630
8-18
Â
125
300
245
210
22
715
8-18
Â
150
320
280
240
24
840
8-23
Â
175
320
310
270
26
885
8-23
Â
200
350
335
295
26
1155
8-23
Â
250
400
405
350
30
1400
8-23
Â
300
450
460
400
30
1800
12-23
Â
Â
Â
GZT644TC Pneumatic Ceramic Double-Disc Gate Valve
Installation, Use & Maintenance:
1. Before Installation, it's necessary to clean the valve and remove possible defects caused in the transportation process.
2.Check carefully whether marks and the nameplate on the valve meet operating requirements.
3. This valve can be insstalled on pipelines at any angle.
4. This valve shall be fully open or fully closed in running and not be used as a throttle valve, or else its sealing surfaces will be washed and get worn faster.
5. For Long term storage, it shall be stored in a dry and ventilated room whth periodic check to avoid rust.
6. Knocking shall be avoided in the transportation process.
Structural Features:
1. Use a Cylinder as the actuator to drive the gate directly to move up and down, with fast opening/closing.
2. The double gates adopt floating connection to produce reliable one-way seal under the medium pressure action. Also the floating connection can drive the gate to rotate up in opening/closing due to misaliginment of axial lines so that the friction grains between the valves' gate and seat are distributed evenly to produce no linear abrasion, thus improving its service life greatly.
3. Sealing surfaces of the valve's body and gate are lined with anti-wear ceramics, with excellent resistance to abrasion.
4. Being compact, it's easy for transportation, installation and maintenance.
Working Principle
When the cylinder drives the gate to move downwards through the valve's stem, sealing surfaces of the valve's gate and body will be engaged to cut off the channel, namely, closing; the other way around is opening.
Main Parts and Materials
Sr No.
Parts
Material
Sr No.
Parts
Material
1
Body
WCB
7
Middle Body
WCB
2
Disc
Ceramic
8
Packing
Flexible Graphite
3
Seat
Ceramic
9
Packing Gland
2Cr13
4
Stem
2Cr13
10
Bracket
Q235
5
Stud
35CrMoVA
11
Pneumatic Actuator
Aluminum Body
6
Nut
25
Â
Â
Â
Application Specification
1. Design and Manufacture: GB/T 12224
2. Face to Face Dimension: Manufacturer's Standard
3. Flange Dimension: JB/T 79.1, ANSI B16.5 Â DIN 2543, JIS B2020
4. Inspection and Test: GB/T 9092
5. Material Standard: GB/T 12229 for Carbon Steel, GB/T 12230 for Stainless Steel
Main External and connecting Dimensions
DN
PN
L
D
D1
C
H
n-d
Â
50
10
200
160
125
16
520
4-18
Â
65
220
180
145
18
595
4-18
Â
80
240
195
160
20
635
8-18
Â
100
280
215
180
20
630
8-18
Â
125
300
245
210
22
715
8-18
Â
150
320
280
240
24
840
8-23
Â
175
320
310
270
26
885
8-23
Â
200
350
335
295
26
1155
8-23
Â
250
400
405
350
30
1400
8-23
Â
300
450
460
400
30
1800
12-23
Â
Â
Â
Model NO.: GZT644TC
Thread Position of Valve Rod: Outside Gate Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage
Suitable Temperature: Below 150 Deg C
Size: Dn50-Dn400
Medium: Dry Ash in Power Plant, Slurry, Cement Ash, Powder
Design Pressure: Pn10, Pn16
Trademark: GOOLE, OEM
Transport Package: Plywood Case
Specification: CE, SGS, GMP
Origin: Wenzhou, Zhejiang, China
HS Code: 8481804090
Model NO.: GZT644TC
Thread Position of Valve Rod: Outside Gate Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage
Suitable Temperature: Below 150 Deg C
Size: Dn50-Dn400
Medium: Dry Ash in Power Plant, Slurry, Cement Ash, Powder
Design Pressure: Pn10, Pn16
Trademark: GOOLE, OEM
Transport Package: Plywood Case
Specification: CE, SGS, GMP
Origin: Wenzhou, Zhejiang, China
HS Code: 8481804090
GZT644TC Pneumatic Ceramic Double-Disc Gate Valve