The product is suitable for fire pumps and showers in hotels, hospitals, shopping malls, supermarkets, high-rise office buildings, theaters, museums, exhibition centers, stadiums, airports, railway stations, subways, industrial and mining enterprises, schools and other public places or large buildings. Daily inspection of fire-fighting facilities such as pumps, periodic inspection of the fire pump, fixed-time, and write-speed inspections. Through automatic inspection, the fire pump is maintained in a reliable state for a long period of time.
Fire pump automatic inspection control equipment

Fire Pump Automatic Inspection Control Equipment Features

● Inspection cycle Each inspection time can be set by itself, and the system can automatically determine whether the fire pump can start normally.

● The patrol inspection of fire-fighting pumps adopts low-frequency and low-speed operation. The patrol inspection power consumption is small, and it will not pressurize the water supply pipe network, and will not increase the mechanical wear of the water pump.

● Immediately after receiving the fire command 0.5 seconds, it will automatically exit the operation and switch to the industrial frequency circuit to ensure normal operation of the fire pump in case of fire.

● During the automatic inspection, the electrical components of the main circuit of the electronic control equipment can be tested to ensure the reliable operation of the electrical control equipment.

● The state and operation process of the water pump detection running are displayed by LED and LCD. The touch screen can set and operate its working state.

● With fault memory function, with RS232, RS485 communication interface, can be networked with the terminal computer to achieve process monitoring.

● With extended functions, optional circuit inspection, pipeline inspection, GPRS communication, printer and control bus communication modules.

● Has the wrong phase, phase loss, undervoltage, overvoltage, overcurrent, short circuit and other protection functions.

● When the fire pump is started, the system uses interlock control on the software to ensure that only one pump is running at any time; when a failure occurs, the system will automatically perform protection.