This machine is with two model.one model with one glue gun,the other with two glue guns. These two glue guns can work together and work separately. Sealant Double Glass Extruder Machine,Insulating Glass Processing Butyl Extruder,Triple Glazing Hot Melt Extruder,Single Glue Insulating Glass Machine JINAN WEILI MACHINE CO LTD , https://www.weiliglassmachine.com
Specifications
Fuel-fired absorption chiller, double effect, the smallest is 58Kw, gas/oil/bio fired, and etc
Fuel -fired absorption chiller(Double effect)
1). Cooling capacity: 58Kw and above
2). Fuel: Natural gas or diesel oil or bio and etc
3). Refrigerator: Water
4). Absorber: Lithium bromide solution
5). Inhibitor: Lithium chromate or Lithium molybdate
NOTE:
1. Rated heating W. Inlet/outlet temp: 55-60° C.
2. Rated hot living W. Inlet/outlet temp: 40-60° C.
3. Fouling factor for chilled W., hot W., cooling W.: 0.086m2k/kw(0.0001m2h° C/Kcal).
4. Pressure limit for chilled W., cooling W.: 0.8MPa.
5. Oil consumption is calculated by low heating value: 10300Kcal/Kg
Coal gas is calculated by high heating value: 3560Kcal/Nm3
Natural gas is calculated by high heating value: 8650Kcal/Nm3
Model
Â
ZX-1 7 5D
ZX- 200 D
ZX-2 3 0D
ZX-2 9 0D
ZX- 350 D
ZX-4 10 D
ZX- 465 D
ZX- 520 D
Cooling capacity
KW
1745
2035
2326
2908
3489
4071
4652
5234
10 4 kcal/h
150
175
200
250
300
350
400
450
USÂ BT
500
583
667
833
1000
1167
1333
1500
H eating capacity
10 4 kcal/h
126
147
168
210
252
294
336
3 78
USÂ BT
420
490
560
700
840
980
1120
1260
C hilled water  or heating water
Flow rate
m3/h
300
350
400
500
600
700
800
900
Pressure loss
MPa
0.1
0.1
0.04
0.04
0.06
0.08
0.1
0.1
Connection diameter
mm
200
250
250
250
300
300
350
350
Cooling  water
Flow rate
m3/h
430
500
571
715
856
1000
1145
1288
Pressure loss
MPa
0.08
0.08
0.09
0.09
0.1
0.09
0.1
0.11
Connection diameter
mm
250
300
300
300
350
350
400
400
H ot water
Flow rate
m3/h
75
87
100
125
150
175
200
225
Pressure loss
MPa
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
Connection diameter
mm
125
125
125
150
150
150
200
200
Gas
oil
C onsumption
C ooling
kg/h
108
126.5
144
180
216
252
287.5
323.5
H eating
kg/h
125.7
146.7
167.6
209.5
251.4
293.3
335.2
377.1
C onnection Dia.
 IN
1/2
1/2
1/2
1/2
1/2
1
1
1
Coal Gas
Consumption
C ooling
Nm3/h
312
364
416.5
520
624
728
831.5
935.5
H eating
Nm3/h
362.9
423.4
483.8
604.8
725.7
846.7
967.6
1088.6
C onnection Dia.Â
mm
80
100
100
100
125
125
125
125
Natural gas
Consumption
C ooling
Nm3/h
128.5
150
171
213.5
256
299
341.5
384
H eating
Nm3/h
149.3
174.2
199.1
248.9
298.7
348.4
398.2
478
C onnection Dia.Â
mm
80
80
80
100
100
100
100
100
Dimension
Length
mm
5670
6200
6880
6880
7400
7400
8300
8300
WeightÂ
mm
3128
3000
3533
3533
3780
3780
3930
3930
Height
mm
2919
3170
3210
3210
3590
3590
3850
3850
Shipping weigh t
T
18.5
22
26
30
34
41
48
55
Specifications
Fuel-fired absorption chiller, double effect, the smallest is 58Kw, gas/oil/bio fired, and etc
Fuel -fired absorption chiller(Double effect)
1). Cooling capacity: 58Kw and above
2). Fuel: Natural gas or diesel oil or bio and etc
3). Refrigerator: Water
4). Absorber: Lithium bromide solution
5). Inhibitor: Lithium chromate or Lithium molybdate
NOTE:
1. Rated heating W. Inlet/outlet temp: 55-60° C.
2. Rated hot living W. Inlet/outlet temp: 40-60° C.
3. Fouling factor for chilled W., hot W., cooling W.: 0.086m2k/kw(0.0001m2h° C/Kcal).
4. Pressure limit for chilled W., cooling W.: 0.8MPa.
5. Oil consumption is calculated by low heating value: 10300Kcal/Kg
Coal gas is calculated by high heating value: 3560Kcal/Nm3
Natural gas is calculated by high heating value: 8650Kcal/Nm3
Model
Â
ZX-1 7 5D
ZX- 200 D
ZX-2 3 0D
ZX-2 9 0D
ZX- 350 D
ZX-4 10 D
ZX- 465 D
ZX- 520 D
Cooling capacity
KW
1745
2035
2326
2908
3489
4071
4652
5234
10 4 kcal/h
150
175
200
250
300
350
400
450
USÂ BT
500
583
667
833
1000
1167
1333
1500
H eating capacity
10 4 kcal/h
126
147
168
210
252
294
336
3 78
USÂ BT
420
490
560
700
840
980
1120
1260
C hilled water  or heating water
Flow rate
m3/h
300
350
400
500
600
700
800
900
Pressure loss
MPa
0.1
0.1
0.04
0.04
0.06
0.08
0.1
0.1
Connection diameter
mm
200
250
250
250
300
300
350
350
Cooling  water
Flow rate
m3/h
430
500
571
715
856
1000
1145
1288
Pressure loss
MPa
0.08
0.08
0.09
0.09
0.1
0.09
0.1
0.11
Connection diameter
mm
250
300
300
300
350
350
400
400
H ot water
Flow rate
m3/h
75
87
100
125
150
175
200
225
Pressure loss
MPa
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
Connection diameter
mm
125
125
125
150
150
150
200
200
Gas
oil
C onsumption
C ooling
kg/h
108
126.5
144
180
216
252
287.5
323.5
H eating
kg/h
125.7
146.7
167.6
209.5
251.4
293.3
335.2
377.1
C onnection Dia.
 IN
1/2
1/2
1/2
1/2
1/2
1
1
1
Coal Gas
Consumption
C ooling
Nm3/h
312
364
416.5
520
624
728
831.5
935.5
H eating
Nm3/h
362.9
423.4
483.8
604.8
725.7
846.7
967.6
1088.6
C onnection Dia.Â
mm
80
100
100
100
125
125
125
125
Natural gas
Consumption
C ooling
Nm3/h
128.5
150
171
213.5
256
299
341.5
384
H eating
Nm3/h
149.3
174.2
199.1
248.9
298.7
348.4
398.2
478
C onnection Dia.Â
mm
80
80
80
100
100
100
100
100
Dimension
Length
mm
5670
6200
6880
6880
7400
7400
8300
8300
WeightÂ
mm
3128
3000
3533
3533
3780
3780
3930
3930
Height
mm
2919
3170
3210
3210
3590
3590
3850
3850
Shipping weigh t
T
18.5
22
26
30
34
41
48
55
After the system heat the hot melt adhesive,the pump pushes
The adhesive,and the glue guns apply the adhesive between the 2 glasses.
The glass can be used after 2 minutes under room temperature.
You do not need to clean the adhesive in the pipes.It can be used after heated again next time.
Model NO.: ZX-
HS Code: 8418692090
Model NO.: ZX-
HS Code: 8418692090