MY-B112  Autoclavable Pipette (Adjustable and Fixed Volume)  All MAYA pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22°C.  Features for MicroPette plus  MY-B112  Autoclavable Pipette (Adjustable and Fixed Volume)  All MAYA pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22°C.  Features for MicroPette plus
We supply Pumps designed for cargo oil unloading aboard oil tankers, and on the basis of many years experience and service records, with the characteristics of: High efficiency; Excellent suction performance for various suction condition; Suitable materials for crude oil or product oil; Construction for minimizing vibration; Rigidity against external force.
Cargo Oil Pump, Marine Twin Screw Pump, Self-Priming Cargo Oil Pump, Cargo Handling Centrifugal Oil Pump, Fuel Transfer Pump Fuente International Co., Ltd. , http://www.shipssp.com
Fully autoclavable
 The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121°C, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
Â
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Manufactured from innovative material
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
Â
Features for multi-channel MicroPette plus
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
MicroPette Plus Single-channel Adjustable Volume Pipettes
Cat No.
Volume Range
Increment
Test VolumeÂ
Maximum permissible systematic error (Inaccuracy)
Maximum permissible random error (Imprecision)
%
μl
%
μl
713111010000
0.1-2.5μl
0.05μl
2.5
2.50%
0.0625
2.00%
0.05
1.25
3.00%
0.0375
3.00%
0.0375
0.25
12.00%
0.03
6.00%
0.015
713111040000
0.5-10μl
0.1μl
10
1.00%
0.1
0.80%
0.08
5
1.50%
0.075
1.50%
0.075
1
Fully autoclavable
 The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121°C, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
Â
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Manufactured from innovative material
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
Â
Features for multi-channel MicroPette plus
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
MicroPette Plus Single-channel Adjustable Volume Pipettes
Cat No.
Volume Range
Increment
Test VolumeÂ
Maximum permissible systematic error (Inaccuracy)
Maximum permissible random error (Imprecision)
%
μl
%
μl
713111010000
0.1-2.5μl
0.05μl
2.5
2.50%
0.0625
2.00%
0.05
1.25
3.00%
0.0375
3.00%
0.0375
0.25
12.00%
0.03
6.00%
0.015
713111040000
0.5-10μl
0.1μl
10
1.00%
0.1
0.80%
0.08
5
1.50%
0.075
1.50%
0.075
1
Model NO.: MY-B112